Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 21
Filter
1.
Braz. oral res. (Online) ; 35: e021, 2021. tab, graf
Article in English | LILACS, BBO | ID: biblio-1153624

ABSTRACT

Abstrac The aim of the present study was to evaluate the cyclic fatigue, torsional resistance and surface roughness of Reciproc R25 instruments in four different situations, namely as new instruments and as instruments tested after clinical preparation of one, two or three maxillary molars with four root canals. The total time required to perform each root canal preparation was recorded. Cyclic fatigue resistance was determined by the time to fracture using a customized testing device (n = 10 per group). The torsional test evaluated the torque and angle of rotation to failure according to ISO 3630-1 (n = 10 per group). The roughness of the working parts of new and used instruments was evaluated with a profilometer (n = 5 per group). Statistical analysis was performed using one-way ANOVA and Tukey's test. The level of significance was set at 5%. No fractures or deformations were observed after clinical use. Higher preparation time was needed during the third use of the instruments for all root canals (p < 0.05). There were no significant differences among the groups in regard to either cyclic fatigue or torsional resistance (p > 0.05). Regarding the roughness measurements, groove depth was higher on new and one- versus two- or three-maxillary-molar-prepared instruments (p < 0.05). It can be concluded that the clinical use of Reciproc instruments increased preparation time and decreased surface roughness. However, clinical use did not affect the cyclic fatigue or torsional resistance of the Reciproc instruments.


Subject(s)
Titanium , Root Canal Preparation , Stress, Mechanical , Materials Testing , Torque , Dental Instruments , Equipment Design
2.
Rev. bras. odontol ; 77(1): 1-4, jan. 2020. tab
Article in English | LILACS | ID: biblio-1102944

ABSTRACT

Objetivo: O presente estudo teve como objetivo avaliar o potencial citotóxico de três diferentes pastas endodônticas em cultura celular de osteoblastos humanos. Material e Métodos: As pastas endodônticas Calen PMCC (SSWhite Artigos Dentários LTDA, Rio de Janeiro, Brasil), Feapex (Fórmula e Ação, São Paulo, Brasil) e CTZ (Lenzafarm, Belo Horizonte, Brasil) foram preparadas e eluídas em meio de cultura celular durante 24 horas em estufa a 37°C e 5% de CO2. Foram realizadas quatro diluições distintas desses meios nas concentrações 1: 1, 1: 2, 1: 4 e 1: 8. Culturas de células de Osteoblastos Humanos da linhagem Saos-2 foram expostas a estas diluições durante 24 horas. O controle negativo foi realizado expondo as células ao meio de cultura sem contato com nenhuma pasta endodôntica. A citotoxicidade desses meios foi avaliada utilizando o ensaio MTT e os resultados foram transformados em porcentagens de células viáveis em relação ao grupo controle negativo. A análise estatística foi realizada com nível de significância de 5%, utilizando ANOVA seguido do teste de Tukey. Resultados: A viabilidade celular foi significativamente alterada de acordo com o material testado (p <0,05) e sua concentração (p <0,05). Em todas as concentrações testadas, a pasta Feapex apresentou maior viabilidade celular comparada aos demais materiais (p <0,05). Embora não tenha sido observada diferença estatisticamente significante entre a pasta Calen PMCC e a pasta CTZ nas concentrações de 1: 1 e 1: 2 (p> 0,05), a pasta CTZ apresentou maior citotoxicidade nas concentrações de 1: 4 e 1: 8 (p <0,05 ). De forma geral, a citotoxicidade diminuiu com o aumento da diluição do material. Conclusão: De acordo com os resultados do presente estudo, a pasta endodôntica Feapex parece ser a melhor opção para utilização entre as pastas analisadas, pois apresentou menor citotoxicidade que as pastas Calen PMCC e CTZ


Objective: The aim of the present study was to evaluate the cytotoxic potential of three different endodontic filling materials on human osteoblast cell cultures. Material and Methods: The endodontic pastes Calen PMCC (SSWhite Dental Articles LTDA, Rio de Janeiro, Brazil), Feapex (Formula and Action, São Paulo, Brazil) and CTZ (Lenzafarm, Belo Horizonte, Brazil) were eluted in cell culture medium during 24 hours in an oven at 37°C and 5% CO2. Four distinct dilutions of these media were performed at the concentrations 1:1, 1:2, 1:4 and 1:8. Cell cultures of Saos-2 Human Osteoblast-like were exposed to these dilutions for 24 hours. The negative control group was performed by exposing the cells to culture medium without contact with any endodontic paste. The cytotoxic potential of these media was evaluated using the MTT assay and the results were transformed into viable cell percentages in relation to the negative control group. Statistical analysis was submitted with a significance level of 5%, using univariate Analysis of Variance (ANOVA) followed by Tukey's test. Results: Cell viability was significantly altered according to the material tested (p<0.05) and its concentration (p<0.05). Feapex samples presented higher cell viability than the other materials in all concentrations tested (p<0.05). Although no statistically significant difference was observed between Calen PMCC paste and CTZ paste at concentrations of 1: 1 and 1: 2 (p>0.05), CTZ paste showed a higher cytotoxicity at concentrations of 1: 4 and 1: 8 (p<0.05). In general, cytotoxicity decreases with increasing material dilution. Conclusion: According to the results of the present study, Feapex endodontic paste seems to be the better option for use among the analyzed pastes, since it presented lower cytotoxicity than Calen PMCC and CTZ pastes


Subject(s)
Root Canal Therapy , Pediatric Dentistry , Endodontics , Root Canal Filling Materials/pharmacology
3.
Rev. bras. odontol ; 73(4): 336-339, Out.-Dez. 2016. ilus, mapas
Article in Portuguese | LILACS | ID: biblio-844053

ABSTRACT

Objetivo: realizar uma revisão sistemática de literatura para verificar as taxas de sucesso do tratamento de dentes permanentes imaturos com periodontite apical após procedimentos tradicionais de apicificação ou de procedimentos de regeneração/revascularização pulpar. Material e Métodos: uma busca eletrônica de artigos foi executada em bancos de dados PubMed e Cochrane, usando termos médicos específicos, entre janeiro de 2000 a junho de 2015. Outras publicações presentes na seção de referência de cada artigo relavante foi analisada a partir de uma busca manual e foram acrescentadas na lista de artigos selecionados. Resultados: inicialmente, um total de 114 títulos foi identificado. Um estudo adicional foi identificado como relevantes após uma busca das listas de referência. Após o enquadramento nos critérios de inclusão e exclusão, apenas dois artigos foram selecionados. Os estudos incluídos demonstram resolução dos sinais clínicos, sintomas e radiolucência periapical para ambas as formas de tratamento. Em contrapartida os estudos foram divergentes no que diz respeito ao aumento de comprimento e espessura radicular após terapias regenerativas; enquanto um estudo apresentou dados mais favoráveis à terapia regenerativa, o outro não demonstrou diferenças entre as duas terapias testadas. Conclusão: a presente revisão sistemática indica a existência de poucos estudos comparando diretamente as duas técnicas avaliadas. Além disso, os protocolos de revascularização oferecem o potencial para tratar dentes permanentes com rizogênese incompleta, com o consequente desaparecimento dos sinais e sintomas e uma maior possibilidade de continuidade de formação radicular quando comparados aos tradicionais procedimentos de apicificação.


Objective: to perform a systematic literature review to evaluate the success rates of treatment of immature permanent teeth with apical periodontitis after traditional procedures like apexification or regeneration/pulp revascularization. Materials and Methods: an electronic search was executed in the PubMed and Cochrane databases using specific medical terms. Articles published between January 2000 and June 2015 were evaluated. Other publications in the reference section of each relevant article were analyzed in a manual search and were added to the selected articles list. Results: at first, a total of 114 titles and resumes was identified after an electronic search in both electronic databases, using a specific combination of terms and keywords. An additional study was identified as being relevant after a reference list search. After the framing in the inclusion/exclusion criteria, only two articles were selected. The included studies demonstrated resolution of clinical signs, symptoms, and periapical radiolucencies to both treatments. On the other hand, these studies were divergent in relation to increased length and root thickness after regenerative therapy; while one of the studies presented more favorable outcomes to regenerative therapy, the other one showed no differences between the two tested therapies. Conclusion: although there are few studies performing a direct comparison between conventional therapies and regenerative therapies, the present systematic review indicates that revascularization protocols offer the potential to treat permanent teeth with incomplete root formation, leading to the disappearance of the signals, symptoms, and an increased possibility of continuing root formation.

4.
Braz. j. oral sci ; 15(3)July-Sept. 2016. ilus
Article in English | LILACS, BBO | ID: biblio-875094

ABSTRACT

Aim: To evaluate the ability of rotary (ProTaper Universal [PTU] and ProTaper Next [PTN]), reciprocating (Reciproc [R] and WaveOne [WO]) and adaptive (Twisted File Adaptive [TFA]) systems in maintaining the original canal profile in straight and curved parts after apical preparations up to size 40. Methods: Resin blocks with simulated curved canals were randomly assigned to five groups: PTU, PTN, R, WO and TFA. Images were captured from each block before and after canal preparation (n=10). Assessment of canal transportation was obtained for the straight and curved parts of the canal. ANOVA followed by Tukey's test was used (α = 5%). Results: Transportation values were increased at the curved part (P = .00). For both canal levels, TFA system induced the lowest mean of canal transportation followed by PTN, R, WO and PTU systems. At the straight portion, transportation for R and TFA systems were similar (P > .05), and these values were significantly lower than for WO, PTN and PTU (P = .00). At the curved portion, TFA resulted in less canal transportation, followed by PTN, R, WO and PTU systems (P = .00). Conclusions: TFA system produced less canal transportation than other systems tested during large apical preparations. (AU)


Subject(s)
Endodontics , Root Canal Filling Materials , Root Canal Preparation
5.
Rev. bras. odontol ; 73(3): 180-185, Jul.-Set. 2016. ilus, tab
Article in Portuguese | LILACS | ID: biblio-844026

ABSTRACT

Objetivo: O presente trabalho teve o objetivo de determinar as dimensões e verificar se os instrumentos X1, X2 e X3 atendem as recomendações da norma ANSI/ ADA nº 101 e se os cones de guta-percha F1, F2 e F3 atendem a norma ANSI/ADA nº 78. Material e Métodos: Os resultados dos instrumentos foram comparados com as dimensões dos cones de guta-percha. Foram utilizados 10 instrumentos e 10 cones de cada tipo. As imagens para análise micromorfométrica foram obtidas com uma lupa Opticam e as medidas determinadas com o software TSView versão 7.2.1.7. Os diâmetros em D3, D6 e D9 reais foram comparados com os nominais pelo teste t-student. Os diâmetros dos instrumentos em D3, D6 e D9 foram comparados com os dos cones pelo teste Anova e complementados com teste de comparações múltiplas SNK. Todos os testes adotaram nível de significância α=5%. Resultados: Os resultados obtidos mostraram que há diferença estatisticamente significante entre as dimensões reais e nominais dos instrumentos (p < 0,05). O instrumento X3 apresentou diferença estatisticamente significante em relação ao cone F1 (p < 0,05), onde os valores do cone são menores do que os dos instrumentos. Conclusão: Dentro das limitações deste estudo pôde-se concluir que: os instrumentos X1 e os cones de guta-percha não atenderam as recomendações de suas normas. O cone F1 pode ser uma opção para obturação dos canais modelados com o instrumento X3, porém a termoplastificação se faz necessária.


Objective: The aim of the present study was to verify if the Protaper Next instruments X1, X2, and X3 and the Protaper Universal gutta-percha cones F1, F2, and F3 meet the ANSI/ADA 101 and 78 recommendations. Material and Methods: The instruments' dimensions were compared with those obtained by the gutta-percha cones. For this, ten instruments and ten cones of each type were used. Micromorphometric images were obtained and analyzed through a stereomicroscope (OptiCam) and measurements were obtained with TSView software, version 7.2.1.7. The D3, D6, and D9 diameters were compared with the nominal diameters using the Student's t-test. After this, the real diameters of the instruments D3, D6, and D9 were compared with the gutta-percha cone diameters by Anova supplemented with SNK test for multiple comparisons. A p ≤0.05 was considered significant. Results: The results showed statistically significant differences between the real diameter and nominal diameter of the instruments (p <0.05). The X3 instrument showed a statistically significant difference when compared to the F1 cone (p <0.05), and the cone values were lower than the instrument values. Conclusion: Within the limitations of this study, it can be concluded that: 1) the X1 instrument and the gutta-percha points did not meet the recommendations, and 2) the F1 cone can be an option for filling the modeled channels with the X3 instrument, but termoplastification is required.

6.
Dent. press endod ; 1(1): 21-27, 2011. ilus, tab
Article in Portuguese | LILACS, BBO | ID: lil-685759

ABSTRACT

A morfologia da superfície dos instrumentos TF® foi estudada utilizando estereomicroscopia e microscopia eletrônica de varredura (MEV). Ensaios mecânicos foram feitos para aferir a flexibilidade e a microdureza. Quatro conicidades de instrumentos TF® foram utilizadas (0,04;0,06; 0,08 e 0,10mm/mm). A estereomicroscopia associada com o programa AxioVision® foi utilizada para medir o ângulo da ponta, a conicidade e o diâmetro da ponta dos instrumentos. A MEV foi utilizada para identificar defeitos na superfície provenientes da fabricação e do acabamento.A flexibilidade e a microdureza foram aferidas com os ensaios de flexão e microdureza Vickers, respectivamente.A análise mostrou que o fabricante atendeu aos valores recomendados pela norma nº 28 ANSI/ADA. Os resultados da microscopia eletrônica de varredura mostraram muitos defeitos de superfície e distorção da aresta lateral dos instrumentos.Foi observado que a flexibilidade do instrumento muda com a conicidade. As forças para induzir a transformação de fase por tensão nos instrumentos com conicidade 0,04; 0,06 e 0,08mm/mm foram de 100gf, 150gf e 250gf,respectivamente. Os valores da microdureza Vickers dos instrumentos são compatíveis com os encontrados nos instrumentos fabricados pelo processo de usinagem.


Objectives: The surface morphology of TF® endodonticinstruments was studied using stereomicroscopy and scanningelectron microscopy (SEM). Mechanical tests weredone for flexibility and microhardness. Methods: Fourtapers of TF® files were used (0.04; 0.06; 0.08 and 0.10mm/mm). The stereomicroscopy associated with the AxioVision® program was used to measure the tip angle, thehelical angle, the taper and the tip diameter of the instruments.SEM was used to identify surface defects due to machiningand finishing. The flexibility and the microhardnesswere measured with bending and microhardness Vickerstests, respectively. Results and Conclusion: The analysisshowed that the manufacturer complied with the valuesrecommended by the ANSI/ADA standard number 28. TheSEM results showed many surface defects and a distortionof the instrument helix. It was observed that the instrumentflexibility changes with its taper. The forces to induce thephase transformation by stress on instruments with taper0.04; 0.06 and 0.08 mm/mm were 100 gf, 150 gf and 250gf, respectively. The values of Vickers microhardness of theinstruments are compatible with rotary instruments manufacturedby the machining process.


Subject(s)
Biomechanical Phenomena , Dental Instruments/standards , Nickel , Titanium , Torque , Torsion, Mechanical
7.
Rev. bras. odontol ; 66(2): 276-279, jul.-dez. 2009. ilus, tab
Article in Portuguese | LILACS, BBO | ID: lil-562678

ABSTRACT

O presente trabalho avaliou a influência da velocidade de rotação no número de ciclos necessários para fraturar instrumentos endodônticos de NiTi mecanizados. Instrumentos ProTaper Universal S2 de 25 mm de comprimento a 300 e 600 rpm foram usados em um canal curvo. Os resultados indicaram que o número de ciclos requerido para causar a fratura foi influenciado pela velocidade de rotação.


Subject(s)
Dental High-Speed Technique , Dental Instruments , Nickel , Root Canal Preparation/instrumentation , Stress, Mechanical , Titanium
8.
Rev. bras. odontol ; 65(2): 202-206, jul.-dez. 2008. ilus, tab
Article in Portuguese | LILACS, BBO | ID: lil-541827

ABSTRACT

O objetivo deste trabalho, in vitro, foi comparar a detecção de canais em 100 pré-molares inferiores humanos por método radiográfico, exame a olho nu, com auxílio de microscópio operatório clínico (MOC), após diafanização, e também analisar a frequência de multiplicidade anatômica dos canais observados. Não houve diferença significativa entre os meios de detecção (Kruskal-Wallis). A maior incidência foi de canais únicos, sendo 52% nos primeiros e 86% nos segundos. Observou-se a presença de três canais em 6% dos primeiros pré-molares. Houve diferença significativa (Mann-Whitney - p<0,0001) na presença de múltiplos canais nos primeiros pré-molares em relação aos segundos.


Subject(s)
Bicuspid , Dental Pulp Cavity/anatomy & histology , Dental Pulp Cavity , In Vitro Techniques , Bicuspid
9.
Rev. bras. odontol ; 65(2): 234-237, jul.-dez. 2008. ilus
Article in Portuguese | LILACS, BBO | ID: lil-541833

ABSTRACT

O presente trabalho avaliou a influência da velocidade de rotação no número de ciclos necessários para fraturar instrumentos endodônticos de NiTi mecanizados. Instrumentos Protaper Universal F3 de 25mm de comprimento a 300 e 600 rpm foram usados em um canal artificial curvo. As superfícies de fratura e as hastes helicodais dos instrumentos fraturados foram analisados usando microscópio eletrônico de varredura (MEV). Os resultados indicaram que o número de ciclos requerido para causar a fratura foi influenciado pela velocidade de rotação. A morfologia da superfície de fratura apresentou característica do tipo dúctil e não ocorreu deformação plástica na haste helicoidal dos instrumentos fraturados.


Subject(s)
Dental High-Speed Technique , Fractures, Stress , Dental Instruments/standards , Nickel , Titanium , Root Canal Therapy/instrumentation
10.
Rev. bras. odontol ; 65(1): 12-17, jan.-jun. 2008. ilus, tab
Article in Portuguese | LILACS, BBO | ID: lil-541691

ABSTRACT

Este estudo analisa a forma de trabalho, as dimensões e a resistência à flambagem de instrumentos endodônticos empregados no caterismo de canais radiculares etresiados. Foram analisados instrumentos C+File, Colorinox e Nitiflex da Dentisply-Maillefer, CC Cord da Antaeos e HI da Miltex. As dimensões foram determinadas no projetor de perfil. As formas foram obtidas no MEV. A resistência à flambagem foi quantificada pela aplicação de uma força na direção axial dos instrumentos. Concluiu-se que os instrumentos C+File apresentaram formas e dimensões diferentes. Os instrumentos C-File apresentam maior resistência à flambagem seguidos pelo CC Cord.


Subject(s)
Compressive Strength , Catheterization/instrumentation , Dental Instruments/standards , Root Canal Preparation/methods
11.
ROBRAC ; 17(43): 65-72, jun. 2008. tab, ilus
Article in Portuguese | LILACS-Express | LILACS | ID: lil-525103

ABSTRACT

O objetivo deste trabalho foi avaliar a influência da conicidade de instrumentos endodônticos de NiTi mecanizados na flexibilidade, no número de ciclos para ocorrer a fratura por fadiga e no comprimentodo segmento fraturado. Foram utilizados 30 instrumentos K3 (Sybron Dental Specialyties, Kerr, México) denúmero 25, comprimento de 25 mm e conicidade de 0,02 - 0,04 e 0,06 mm/mm. A flexibilidade dos instrumentosfoi avaliada em ensaio de flexão em cantilever. O número de ciclos para ocorrer a fratura por fadigafoi determinada em ensaio de flexão rotativo. Os resultados obtidos indicaram que a flexibilidade e a vidaem fadiga diminuiu com o aumento da conicidade e o comprimento do segmento fraturado aumentou com oaumento da conicidade dos instrumentos.


The aim of this study was evaluate the influence of engine-driven instrument taper on flexibility, cyclesto fracture occur and length of the fractured segment. Thirty K3 (Sybron Dental Specialties, Kerr, Mexico) instruments size 25 taper .02, - .04 e .06 with 25mm in length were used. The flexibility was evaluated in cantileverbending test and the cycles to fracture occur was obtained in rotating-bending test. The results indicatedthat the flexibility and the fatigue resistance decreased in the instruments with more taper, in the other hand,the length of the fractured segment increased in the instrument with more taper.

12.
Rev. bras. odontol ; 64(1/2): 129-136, 2007. ilus, graf
Article in Portuguese | LILACS, BBO | ID: lil-541867

ABSTRACT

O objetivo do trabalho é avaliar se o movimento de alargamento como giro contínuo obtido por meio de contra-ângulo redutor de velocidade acoplado em um motor elétrico e o movimento de alargamento com giro alternado obtido por meio de um contra-ângulo especial acoplado em motor elétrico, empregando-se instrumentos endodônticos de aço inoxidável (FlexoFile) e de níquel-titânio (K³ e Nitiflex) exercem influência no desgaste das paredes no segmento apical curvo de canais artificiais. Para a avaliação do desgaste foram realizadas fotografias digitais pré e pós-operatórias por meio de uma câmera digital que captou as imagens com o auxílio de um referenciador fotográfico que garantiu que as imagens sempre estivessem no mesmo plano, preservando assim, a padronização das fotografias. Em funçao dos resultados, concluimos que a natureza da liga metálica (n=NiTi ou aço inoxidável) dos instrumentos endodônticos empregados assim como o movimento de alargamento contínuo ou alternado gerados por meios mecânicos não interferiram nos resultados obtidos.


Subject(s)
Dental Instruments , Nickel , Root Canal Preparation/methods , Radiography, Dental, Digital , Stainless Steel , Titanium
13.
ROBRAC ; 15(40): 71-77, dez. 2006. tab, ilus
Article in Portuguese | LILACS-Express | LILACS | ID: lil-527932

ABSTRACT

No presente trabalho avaliou-se o valor da carga necessária para induzir uma determinada deformação elástica (deslocamento) de instrumentos de NiTi acionados a motor de mesma conicidade nominal e de diferentes números de três marcas comerciais. Nos ensaios mecânicos de flexão as amostras foram fixadas em uma das extremidades (cantilever) e a carga aplicada na extremidade oposta. Os resultados obtidos indicaram que os instrumentos da marca comercial ProFile estatisticamente são mais flexíveis(menor rigidez) do que os K3 eHero em todos os números (diâmetros) ensaiados


In this study the lood needed to provide certain elastic deformation (desplacement) in engine-driven NiTi instruments, with similar sizes (nominal diameter), from three commercial brands was evaluated. In the bending tests, the sampes were fixed at one end (cantilever) and then the lood was applied at other end. The results showed that the ProFile instruments were more flexible than K3 and Hero instruments in all tested sizes.

14.
Rev. paul. odontol ; 28(1): 8-13, jan.-mar. 2006. ilus
Article in Portuguese | LILACS, BBO | ID: lil-532680

ABSTRACT

A geometria da haste helicoidal dos instrumentos endodônticos de NiTi acionados a motor apresenta uma variação acentuada de formas e dimensões oriundas do processo de fabricação. A geometria da haste helicoidal é uma característica importante no desenho do instrumento, que pode interferir na instrumentação de canais radiculares. O objetivo deste trabalho foi realizar um estudo crítico da geometria (formas e dimensões) das hastes helicoidas de instrumentos endodônticos de NiTi acionados a motor. A conclusão deste trabalho mostrou que os instrumentos endodônticos de NiTi acionados a motor apresentam: hastes helicoidais com valores variáveis em relação à geometria, seções retas transversais com diferentes formas e áreas, e ângulos de ataques negativos.


Subject(s)
Dental Pulp Cavity , Endodontics , Dental Instruments
15.
Rev. bras. odontol ; 63(3/4): 280-284, 2006. ilus, graf
Article in Portuguese | LILACS, BBO | ID: lil-541689

ABSTRACT

No presente trabalho avaliou-se a força máxima de flexão de espaçadores endodônticos digitais de aço inoxidável e de níquel-titânio identificados pelas letras A, B, C e D, fabricados pela Dentsply - Maillefer, Suíça. Nos ensaios mecânicos de flexão, as amostras foram fixadas em uma das extremidades e a força foi aplicada na oposta (flexão em cantilever). Estatisticamente, os espaçadores endodônticos digitais de níquel-titânio são menos rígidos e mais flexíveis do que os de aço inoxidável. Para espaçadores de mesma liga metálica, a flexibilidade diminuiu com o aumento da conicidade da haste metálica.


Subject(s)
Compressive Strength , Dental Instruments/standards , Nickel , Pliability , Stainless Steel , Titanium
16.
Rev. bras. odontol ; 63(1/2): 113-116, 2006. ilus, tab
Article in Portuguese | LILACS, BBO | ID: lil-438471

ABSTRACT

No presente trabalho, avaliou-se a resistência à fratura de instrumentos endodôntios de NiTi acionados a motor quando submetidos ao ensaio de torção e flexão. As características morfológicas da superfície de fratura foram analisadas por microscopia eletrônica de varredura (MEV). Foram utilizados instrumentos de número 25, de conicidades nominais 0,02-0,04 e 0,06 mm/mm com comprimentos de 25 mm das marcas comerciais Hero (Micromega, França) e Race (FKG, Alemanha). Os resultados obtidos indicaram que os instrumentos Hero quando comparados aos Race apresentaram maior resistência mecânica quanto ao torque máximo de fratura, enquanto a avaliação no MEV indicou fratura do tipo dúctil


Subject(s)
Dental Instruments/standards , Materials Testing , Microscopy, Electron, Scanning , Torque
17.
UFES rev. odontol ; 7(1): 6-10, jan.-abr. 2005. ilus, tab
Article in Portuguese | LILACS, BBO | ID: lil-466458

ABSTRACT

Este estudo comparou, mediante ensaio de flexão engastado, o valor da carga necessária para uma determinada deformação elástica (deslocamento) de um instrumento endodôntico tipo K, fabricado em aço inoxidável. Foram utilizados instrumentos endodônticos de 31mm de comprimentos, número 35, com conicidade 0,02mm/mm, da marca comercial CCCord (Antaeos, Alemanha). Todos os instrumentos tiveram seus cabos removidos antes dos ensaios mecânicos. Esse procedimento conferiu aos instrumentos hastes metálicas de cerca de 37mm de comprimento. Todas as amostras foram utilizadas nos três ensaios de flexão propostos, ou seja, as distâncias entre os pontos de fixação dos intermediários dos instrumentos no dispositivo empregado no ensaio de flexão, em relação às extremidades (ponta), foram de 20, 25 e 30mm. Os resultados obtidos indicaram que a flexibilidade variou em função do comprimento do instrumento. A carga máxima de flexão diminuiu em relação ao aumento do comprimento do instrumento endodôhtico


Subject(s)
Dental Instruments , Pliability
18.
Rev. bras. odontol ; 62(1/2): 115-118, 2005. ilus, mapas, tab
Article in Portuguese | LILACS, BBO | ID: lil-427980

ABSTRACT

No presente trabalho, avaliou-se a carga necessária elástica (deslocamento) de instrumentos de NiTi acionados a motor de mesmo número (diâmetro nominal) de três marcas comerciais. Nos ensaios mecânicos de flexão, as amostras foram fixadas em uma das extremidades (cantilever) e a carga aplicada na extremidade oposta na direção perpendicular ao eixo do instrumento. Os resultados obtidos indicaram que os instrumentos da marca comercial ProTaper são mais rígidos (menos flexíveis) do que os ProFile e K³ em todos os números (diâmetros nominais) ensaiados


Subject(s)
Dental Instruments/standards , Pliability
19.
Rev. bras. odontol ; 62(3/4): 281-284, 2005. tab, mapas
Article in Portuguese | LILACS, BBO | ID: lil-541762

ABSTRACT

No presente trabalho, avaliou-se as características geométricas e o acabamento superficial de espaçadores endodônticos digitais de aço inoxidável e de níquel-titânio identificados pelas letras A, B, C e D, fabricados pela Dentsply-Maillefer, Suiça. Os resultados obtidos indicaram que os espaçadores de aço inoxidável e de níquel-titânio apresentaram: vértices das pontas com formas diferentes; diâmetros, conicidades e comprimentos semelhantes; segmentos cônicos das hastes metálicas com comprimentos e acabamentos superficiais diferentes.


Subject(s)
Dental Polishing , Dental Instruments/trends , Stainless Steel , Titanium
20.
Rev. bras. odontol ; 61(3/4): 210-212, 2004. tab
Article in Portuguese | LILACS, BBO | ID: lil-412352

ABSTRACT

O objetivo deste estudo foi avaliar a influência da frequência da rotação alternada no tempo e ponto de fratura de instrumentos tipo K de NiTi. Foram utilizadas 20 limas Nitiflex n° 35 de 25mm de comprimento (Maillefer, Suiça). Os instrumentos foram divididos em 2 grupos e avaliados em um canal simulado curvo em duas frequências obtidas por meio de um contra-ângulo redutor de 10:1, acoplado em motor elétrico nas velocidades nominais de 8.000 e 30.000 rpm. Os resultado foram submetidos à análise estatística concluindo-se que a frequência de rotação alternada influenciou na vida útil dos instrumentos analisados. O ponto de fratura localizou-se próximo ao centro da parte curva do instrumento. A localização do ponto de fratura não foi alterada com a mudança da frequência de rotação alternada


Subject(s)
Dental Instruments/standards , Root Canal Preparation/standards , Root Canal Preparation , Nickel , Titanium
SELECTION OF CITATIONS
SEARCH DETAIL